Xantrex XW6048 Inverter Charger
Tools & Home Improvement >>> Electrical & Solar
Xantrex XW6048 Inverter/Charger
BEST PRICE ON LINE AUTHORIZED DEALER
Xantrex XW6048 Inverter/Charger
Start Price USD 3,425.00
Current Price USD 3,425.00
Time Left -
Bid Count 0
Buy It Now Price -
Reserve Price -
Start Time Friday, October 03, 2008
End Time Friday, October 10, 2008
Location TELLICO PLAINS, TN

See more about 'Xantrex XW6048 Inverter/Charger'

Description
READY MADE RESOURCES IS A PROUD AUTHORIZED DEALER OF SUNNY BOY PRODUCTSIF YOU HAVE ANY QUESTIONS ON THIS PRODUCT PLEASE CALL US AT 800-627-3809WE WELCOME INTERNATIONAL SALESPAYMENT METHOD MUST BE APPROVED FOR INTERNATIONAL SALESWE ARE APPROVED FOR THE CALIFORNIA REBATE PROGRAM Xantrex XW Hybrid Inverter/Chargers XW4024, XW4548, XW6048 Xantrex brings the next generation of inverter/charger to market, with the XW Hybrid Inverter/ Charger, the heart of the XW System. The XW Hybrid Inverter/Charger (XW) is a true sine wave, 120/240-volt AC, split-phase, inverter/charger that incorporates a DC to AC inverter, a battery charger, and an AC auto-transfer switch. It is the foundation for battery- based residential and commercial applications up to 18 kilowatts (kW). Capable of being grid-interactive or gridindependent, the XW can operate with generators and renewable energy sources to provide full-time or backup power. Designed with consultation and input from industry experts, dealers, and installers, the XW sets a new standard for battery-based inverter/chargers. Integrating the best features available in the market, innovative new features by Xantrex and balance-of-systems components, the XW Hybrid Inverter/Charger’s design makes installation quicker and easier. The XW offers high efficiency and unprecedented surge capacity to maximize the owner’s return on investment. No other inverter/charger looks or performs like the XW.   Features True sine wave output 120/240 volt AC spilt-phase operation Dual AC inputs Integrated design to minimize external balance-of-system components XanBus™-enabled network communication Certified to UL1741 and CSA for utility-interactive applications Unprecedented surge capacity Efficient, power factor corrected, high-current, multistage battery charging Optional Accessories:   Specifications Electrical Specifications XW6048-120/240-60 XW4548-120/240-60 XW4024-120/240-60 Continuous output power 6,000 W 4500 W 4000 W Surge rating (10 seconds) 12,000 W 9000 W 8000 W Surge current L-N: 105 Arms (7 sec) L-L: 40 Arms (20 sec) L-L: 52.5 Arms (7 sec) L-N: 70 Arms (20 sec) L-N: 75 Arms (20 sec) L-L: 35 Arms (20 sec)> Waveform True sine wave True sine wave True sine wave Low-load efficiency 95% 95% 95% Idle consumption - search mode < 8 W < 8 W < 8 W AC connections AC1 (Grid), AC2 (Generator) AC1 (Grid), AC2 (Generator) AC1 (Grid), AC2 (Generator) AC voltage 120/240 Vac split-phase 120/240 Vac split-phase 120/240 Vac split-phase AC input breaker 60 A two-pole 60 A two-pole 60 A two-pole Utility interactive Yes Yes Yes CEC weighted efficiency 92.5% 93% 91% CEC power rating 5752 W 4500 W 4000 W AC input voltage range (bypass/charge mode) L-N: 80 - 150 Vac (120 V nominal); L-L: 160 - 270 Vac (240 V nominal) AC input frequency range (bypass/charge mode) 55 - 65 Hz (default); 44 - 70 Hz (allowable) AC1 voltage range – Sell mode (automatically adjusts when entering Sell mode)* L-N: 108 - 130 +/- 1.5 Vac; L-L: 214 - 260 +/- 3.0 Vac AC1 frequency range – Sell mode (automatically adjusts when entering Sell mode)* 59.4 - 60.4 +/- 0.05 Hz AC output voltage L-N: 120 Vac +/- 3%; L-L: 240 Vac +/- 3% AC output frequency 60.0 +/-0.1 Hz DC current at rated power 130 A 96 A 178 A Total harmonic distortion < 5% Automatic transfer relay 60 A Typical transfer time 8 ms DC input voltage (nominal) 50.4 Vdc 50.4 Vdc 25.2 Vdc DC input voltage range 44 - 64 Vdc 44 - 64 Vdc 22 - 32 Vdc Maximum continuous charge rate 100 A 85 A 150 A Efficiency at maximum charge rate 89.4% 90.2% 85.8% Power factor corrected charging 0.98 0.98 0.98 Emissions FCC Class B FCC Class B FCC Class B Multiple-unit configurations Up to three parallel units in 120/240-volt split-phase configuration Auxiliary relay output 0-12 Vdc, maximum 250 mA DC Non-volatile memory Yes Yes Yes System network Xanbus™ (publish-subscribe network, no need for hubs or special cards) Mechanical Specifications   Mounting Wall mount, backplate included Inverter dimensions (H x W x D) 23 x 16 x 9” (580 x 410 x 230 mm) Inverter weight 125 lb (57 kg) 115 lb (52 kg) 115 lb (52 kg) Shipping dimensions 28 x 22 ¼ x 10 ½” (711 x 565 x 267 mm) Shipping weight 132 lb (60 kg) 122 lb (55 kg) 122 lb (55 kg) Display panel Status LEDs indicate AC In status, faults/warnings, equalize mode, battery level. Three-character display indicates output power or charge current, fault/warning codes. On/Off and equalize buttons Battery temperature sensor Included Included Included Standard warranty Five years Five years Five years Part number 865-1000 865-1005 865-1010 Environmental Specifications   Enclosure type NEMA Type 1 – Indoor (sensitive electronic components sealed inside enclosure) Operational temperature range -13 to 158 °F (-25 to 70 °C) Accessories   Remote display Optional XW System Control Panel monitors and configures all devices connected to Xanbus™ Network Generator support Optional XW Automatic Generator Start module connects to Xanbus™ Network. Automatically activates generator to recharge depleted battery bank or assist inverter with heavy loads Power distribution & panel conduit boxes Optional balance-of-systems components for NEC compliant installations, includes pre-wired AC and DC circuit breakers, bus bars and multiple knockouts for conduit and additional breakers Regulatory Approvals UL 1741 1st Edition: 2005 Version CSA 107.1-01    S

Place a Bid!


Search
 

Categories
Switch Plates & Outlet Covers
Switches & Outlets
Connectors & Ties
Alternative & Solar Energy
Extension Cords
Circuit Breakers & Fuse Boxes
Other

More related categories
Multi-Toggle
Other
Outlet
Outlet
Single Toggle

 
eBay Developers Program Member

 [home] [sitemap]
12/2/2008 8:49:16 PM